Key takeaways
- Sentinel events require a comprehensive systematic analysis and action plan within 45 business days. Reporting to The Joint Commission is encouraged, not required.
- Use a team of 4–6 people, per RCA². Interview the people involved in the event, but keep them off the team.
- Aim for at least one stronger or intermediate action per cause. Training and policy reminders alone are weak.
- Give every action an owner, a due date and a measure, then check that it worked.
What root cause analysis is
Root cause analysis (RCA) is a structured method for finding out why an adverse event or close call happened: the underlying system weaknesses that allowed it, not just the immediate trigger. The goal is to change those conditions so similar events do not happen again.
RCA is not a disciplinary investigation. Individual errors are usually symptoms of how the work is designed, so a good RCA asks what made the error likely. Events involving criminal acts, patient abuse, impairment from alcohol or drugs, or deliberately unsafe acts are handled through separate administrative processes. The National Patient Safety Foundation recommends that each organization define these "blameworthy" events in advance.
Common analysis tools include:
- Flow diagrams and timelines that reconstruct what happened, step by step.
- Cause-and-effect (fishbone) diagrams that sort contributing factors into categories such as people, process, equipment and environment.
- 5 Whys, which asks "why?" repeatedly until the team reaches a cause it can act on.
- Fault tree analysis, which maps how conditions combine to produce the event.
What The Joint Commission expects after a sentinel event
Under The Joint Commission's Sentinel Event Policy, a sentinel event is a patient safety event, not primarily related to the natural course of the patient's illness, that reaches a patient and results in death, permanent harm or severe harm. Accredited organizations must complete a comprehensive systematic analysis, most commonly an RCA, and a corrective action plan within 45 business days of the event or of becoming aware of it. They must then implement the plan and monitor whether it works.
Reporting a sentinel event to The Joint Commission is strongly encouraged but not required. If The Joint Commission learns of the event another way, the organization is expected to submit its analysis and action plan. The policy asks that the analysis focus on systems and processes rather than individual performance.
ImprovementFlow
Root Cause Analysis
ImprovementFlow lets a team start a root cause analysis straight from a safety event, work the root causes with tools like 5 Whys and fishbone diagrams, and give each corrective action an owner, a due date and a linked measure.
RCA²: making the analysis lead to action
In 2015 the National Patient Safety Foundation, which later merged with IHI, published RCA²: Improving Root Cause Analyses and Actions to Prevent Harm. It renamed the process "root cause analysis and action" to stress that an analysis only matters if it produces actions that work. Its recommendations include:
- Prioritize with a transparent, risk-based system, and review close calls as well as harm events.
- Start within 72 hours of recognizing that a review is needed, and finish within 30–45 days.
- Use a team of 4–6 people, including process experts and people from all levels of the organization, and consider a patient representative unrelated to the event.
- Interview the people involved in the event, but don't put them on the team.
- Give team members time to do the work during their normal shift.
- Find at least one stronger or intermediate-strength action for each cause, with a process or outcome measure for each action.
- Have leaders approve and periodically review actions, and give feedback to the staff involved and to patients and families.
Choosing actions that work: the action hierarchy
The most common way an RCA fails is a weak action plan. When researchers reviewed eight years of RCAs at a US academic medical center, the most common of 731 proposed solutions were training (20%), process change (19.6%) and policy reinforcement (15.2%). Several event types recurred during the study period despite repeated RCAs.
The action hierarchy used in RCA², which comes from the VA National Center for Patient Safety, ranks actions by how little they depend on people remembering to do the right thing:
- Stronger actions change the design of the work: forcing functions, physical changes, simplified processes, standardized equipment.
- Intermediate actions make the right thing easier: checklists, redundancy, software enhancements, reduced workload.
- Weaker actions rely on memory and vigilance: double checks, warnings, new policies and training.
Sources
Making corrective actions stick
Writing the action plan is the midpoint, not the end. The actions that prevent a repeat are the ones that get done, get measured and get checked.
- Give every action a named owner and a due date, and track it where leaders can see it.
- Attach a measure to each action, such as how often a new process step is completed, and decide in advance when you will look.
- Look across RCAs, not only within them. When several reviews point to the same cause, such as look-alike packaging or an unclear handoff, a single system fix can answer them all.
- Review close calls in the same high-risk categories. They point to the same weaknesses as harm events and are far more common.
How ImprovementFlow supports RCA follow-through
- Reviewers can open a linked A3 improvement project directly from a safety event, so the analysis stays connected to the report that started it.
- The team works the root causes on the project with tools such as 5 Whys and fishbone diagrams.
- Each plan step carries an owner, a team and a due date, and linked metrics show whether the outcome is moving.
- Safety Reporting lets reviewers look across events by department, severity and tag to see which problems keep coming back.